OhmWorks Articles

18 articles on cable sizing, voltage drop, PV/solar DC sizing, and earthing/grounding — across the Philippine Electrical Code, AS/NZS Standards, and the NEC.

Cable Sizing All Codes

Why Cable Sizing Needs Two Checks, Not One

A cable has to pass both an ampacity check and a voltage drop check — whichever demands the bigger conductor wins. Here is why skipping either one is a real risk.

PEC Cable Sizing

PEC Cable Sizing: A Worked Example, Step by Step

A concrete walkthrough of sizing a branch circuit cable under the Philippine Electrical Code — from design current to the final, derated recommendation.

Voltage Drop Code Comparison

Voltage Drop Limits Across PEC, AS/NZS, and NEC — What Actually Differs

All three codes care about voltage drop for the same underlying reason, but the exact limits and how they are applied are not identical. Here is the comparison.

Solar PV All Codes

Sizing PV/Solar DC Cable: The 1.25×Isc Rule Explained

A near-universal safety multiplier shows up in PV cable sizing under PEC, AS/NZS 5033, and the NEC. Here is why it exists and how it is applied.

Earthing Safety

Earth Fault Loop Impedance (Zs) Explained

A low earth fault loop impedance is what makes a circuit breaker actually protect you during a fault. Here is what Zs measures and why it matters.

PEC Solar Financial

How OhmWorks Calculates Solar Payback Period

System size, energy production, monthly savings, and payback period — the methodology behind the Solar System Sizing & Savings calculator, explained in full.

AS/NZS Code Comparison

AS/NZS 3008.1.1: How Australian Cable Sizing Differs from PEC

Same underlying physics, different reference tables and derating conventions. A practical comparison for anyone working across both codes.

AS/NZS Solar PV

AS/NZS 5033 and DC Isolators: What Solar Installers Must Get Right

Isolator voltage rating, DC arc interruption, and IP rating are three places installers commonly get an AS/NZS 5033 solar DC installation wrong.

AS/NZS Earthing

AS/NZS 3000 Earthing: The MEN System Explained

Australia uses a Multiple Earthed Neutral system rather than a purely separate earth conductor scheme. Here is what that means for solar and general installations.

NEC Cable Sizing

Reading NEC Table 310.15(B)(16): Ampacity the American Way

The NEC’s primary ampacity table looks intimidating at first glance. Here is how to actually read it, column by column.

NEC Voltage Drop

NEC's Voltage Drop Guidance — Where It Actually Comes From

Unlike ampacity, the NEC frames voltage drop as an informational recommendation rather than a numbered rule. Here is what that distinction means in practice.

NEC Solar PV

NEC Article 690: Sizing PV Source and Output Circuit Conductors

Article 690 governs solar PV installations under the NEC, with its own conductor sizing logic layered on top of the general ampacity tables.

NEC Grounding

Grounding Electrode Conductor Sizing: NEC Table 250.66 Explained

Table 250.66 has separate columns for copper and aluminum service conductors — using the wrong column is a real, easy-to-make mistake.

Code Comparison All Codes

PEC vs AS/NZS vs NEC: Three Philosophies, One Physics

Ampacity plus voltage drop, temperature derating, grouping correction — the underlying physics is identical across all three codes. Here is what actually differs.

Earthing Code Comparison

Earthing and Grounding: How Three Codes Solve the Same Problem Differently

PEC, AS/NZS, and the NEC all protect against the same fault hazard, but the terminology, systems, and sizing tables are not interchangeable.

Cable Sizing Practical

Five Cable Sizing Mistakes That Show Up on Real Job Sites

Undersized-by-eye estimates, forgotten derating, and mismatched termination ratings — the recurring mistakes that turn up in real installations.

Cable Sizing Derating

Temperature and Grouping Derating: The Two Factors Everyone Forgets

A cable’s headline ampacity rating is a best-case number. Here is what actually reduces it in a real installation, and why both corrections matter together.

Solar PV Code Comparison

A Solar Installer's Guide to DC Cable Sizing Across Three Codes

One installer working projects under different codes needs one consistent mental model for PV DC cable sizing — here is that model, mapped to each code.